<*n style="font-size:10.5pt"><*n style="font-family:"Times New Roman""><*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:宋体"><*n style="color:#000000"><*n style="font-family:宋体">产品简介*n>*n>*n>*n>*n><*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:'Times New Roman'"><*n style="color:#000000">:*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333">15ppm<*n style="font-family:宋体">舱底水报警装置是新一*测污水中含微量油份浓度的在线监测仪器,适用于舰、船舶舱底油污水排放的连续监测,具有*n><*n style="font-family:Arial">15ppm*n><*n style="font-family:宋体">超限报警和控制污水排放功能。它一般与*n><*n style="font-family:Arial">15ppm*n><*n style="font-family:宋体">舱底油污水分离器配套使用。*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333">15ppm<*n style="font-family:宋体">舱底水报警装置通过中国船级社*n><*n style="font-family:Arial">(CCS)*n><*n style="font-family:宋体">型式认可,性能指标符合国际海事*海上环境保护**n><*n style="font-family:Arial">MEPC.107*n><*n style="font-family:宋体">(*n><*n style="font-family:Arial">49*n><*n style="font-family:宋体">)决议要求。*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">性能特点:*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333">1.<*n style="font-family:宋体">采用的多波段红外测量原理及微处理技术,反应时间快,测量精度高;*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333">2.<*n style="font-family:宋体">整体采用防电磁干扰设计,克服使用环境对仪器的影响,****仪器的系统稳定性和可靠性;*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333">3.<*n style="font-family:宋体">实时显示油份浓度、系统工作状态;*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333">4.<*n style="font-family:宋体">实时记录各种报警状态数据并自动储存,随时查询历史数据;*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333">5.<*n style="font-family:宋体">测量室便于维护和清洗,操作简单;*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333">6.<*n style="font-family:宋体">仪器具有工作状态监控功能,在仪器故障、维修或更换时可自动控制超标污水的排放。*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">规格参数*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">范*n> <*n style="font-family:宋体">围:*n><*n style="font-family:Arial">0-30mg/l*n><*n style="font-family:宋体">可扩展到*n><*n style="font-family:Arial">50mg/l*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">精*n> <*n style="font-family:宋体">度:优于*n><*n style="font-family:Arial">2mg/l*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">线*n> <*n style="font-family:宋体">性:高于*n><*n style="font-family:Arial">2%*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">显*n> <*n style="font-family:宋体">示:*n><*n style="font-family:Arial">LCD*n><*n style="font-family:宋体">显示*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">供*n> <*n style="font-family:宋体">电:*n><*n style="font-family:Arial">220VAC/110VAC &plu*n;10% 50Hz/60Hz 5%*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">功*n> <*n style="font-family:宋体">率:*n><*n style="font-family:Arial">10VA*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">报*n> <*n style="font-family:宋体">警*n> <*n style="font-family:宋体">点:*n>1-15ppm*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">报警点出厂设置:*n>15ppm*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">报警输出:*n>2<*n style="font-family:宋体">路继电器输出*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">报警继电器输出触点额定值:*n>5A<*n style="font-family:宋体">,*n><*n style="font-family:Arial">250VAC*n><*n style="font-family:宋体">,非**n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">报警指示:红色*n>LED*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">输出信号:*n>4-20mA, <*n style="font-family:宋体">负载电阻*n><*n style="font-family:Arial">?500*n><*n style="font-family:宋体">欧*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">样品水压:*n>0.01<*n style="font-family:宋体">-*n><*n style="font-family:Arial">6bar*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">环境温度:*n>0<*n style="font-family:宋体">到*n><*n style="font-family:Arial">+55*n><*n style="font-family:宋体">摄氏度*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">样品水温:*n>+1<*n style="font-family:宋体">到*n><*n style="font-family:Arial">+80*n><*n style="font-family:宋体">摄氏度*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">尺*n> <*n style="font-family:宋体">寸:*n><*n style="font-family:Arial">360mm×240mm×105mm*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">防护等级:*n>IP45*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">重*n> <*n style="font-family:宋体">量:*n><*n style="font-family:Arial">8KG*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">管道连接:*n>R 1/4”<*n style="font-family:宋体">内螺纹*n>*n>*n>*n>*n>
<*n style="font-size:14.0000pt"><*n style="background-color:#ffffff"><*n style="font-family:Arial"><*n style="color:#333333"><*n style="font-family:宋体">符合标准:*n>IMO.Res.MEPC.107<*n style="font-family:宋体">(*n><*n style="font-family:Arial">49*n><*n style="font-family:宋体">)*n>*n>*n>*n>*n>*n>*n>
XOC-01 15ppm油温浓度油水分离器报警装置油污水处理器
1、概述
XOC-01型15ppm舱底水报警装置用于船舶舱底油污水的连续检测,也可用于化工、石油、环保等领域用于含油污水的监测。
本仪器经中国船级社型式认可,技术性能符合MEPC.107 (49)决议(2003年7月18日通过)《修订的船舶机器处所舱底水防污染设备指南和技术条件》中第2部分《15 ppm舱底水报警装置型式认可试验和性能技术条件》以及第3部分《防污染设备型式认可环境试验技术条件》的规定。仪器设计结构紧凑、牢固,防护等级为IP45,完全适合于船舶机舱等环境工作。
XOC-01型15ppm舱底水报警装置,具有测量结果显示、15PPm报警值设定、污水达标排放控制和正比于测量值的模拟信号输出、提供数据打印以及历史数据储存和查询等一系列功能。
XOC-01型15ppm舱底水报警装置可以记录日期、时间和报警状态以及运行状态。
2、性能指标
测量范围: 0~30PPm(当测量值>40ppm时,显示值为80)
测量精度: &plu*n;5PPm
报警指示: 两个发光二****管
浓度值显示: 三位LED
报警工作点: 15PPm
报警继电器触点负载能力: 5A/220V
供液压力: 0.01~0.5MPa
重 量: 约13.5Kg
电 源: AC220&plu*n;10% 50Hz&plu*n;5%
功 耗: 20W
防护等级: IP45
使用工作环境:
温度0~55℃,相对湿度95~100%中正常工作。
3、结构简介
XOC-01型15ppm舱底水报警装置的结构示。
仪器的主要部件为测量室中光电转换器,在仪器面板上装有数据显示板和操作键盘,仪器面板下部装有微型打印机。仪器箱体内部有数据处理电路板,电源和输出部件以及数据打印输出信号,包括电源开关、保险丝盒、电源变压器、电源滤波器、报警控制继电器、输出接线柱等。
4、使用方法
4.1 安装
4.1.1 箱体固定
XOC-01型15ppm舱底水报警装置用四个M8螺栓将仪器垂直安装固定在安装部位。仪器在安装时应尽可能地靠近油水分离器的取样点,从而避免因取水样产生*导致报警动作的*,仪器的四周应有足够的空间以便日常维护。
4.1.2管路连接
仪器与外部管路连接参见附图三。
管路安装推荐采用φ8×1mm紫铜管,仪器箱体左侧的管路接头为取样水进口接头,出水接头在测量室顶部的出口部件上,管路间的连接均采用标准卡套接头。仪器上有用于无油清水和取样水转换的球阀。样水采集点应考虑选择在分离器排放管的垂直部件上,以减少样液中所夹带的空气,使仪器的玻璃管内充满自下而****动的样液。
注意:在整个取样管路上,不能安装任何阀门。
4.1.3 开、关箱门
仪器在运行时,请把仪器的箱门关好并*,否则仪器报警。如因接线、开或关仪器等必须打开箱门时,请按以下步骤进行操作:
(1)把随机配带的*正确地插入锁孔中。
(2)左手用力按住箱门靠近锁孔的边缘不放,使箱门有一个稍微向下的位移,同时用右手逆时针转动*90度。
(3)用手将箱门打开。
关箱门的操作步骤如下:
(1)把随机配带的*正确地插入锁孔中。
(2)合上箱门,左手用力按住箱门靠近锁孔的边缘不放,使箱门有一个稍微向下的位移,同时用右手顺时针转动*90度。
(3)拔出*并妥善保管好,以备下次开箱时使用
4.1.4 接线
打开仪器箱门,可以看到在箱体底部12个接线端子,电源、以及控制电磁阀的电缆从仪器底部四个φ20mm的填料函中穿过与接线端子相连接。典型端子排接线图见附图四。
其中,1号和2号接线端子为仪器外接电源,用来给仪器提供工作电源;3号和4号接线端子为辅助电源,可以用来给被控的以及电磁阀提供工作电源;5、6、7号接线端子对应报警继电器1的辅助触点,6号端子为公共点,8、9、10号接线端子对应报警继电器2的辅助触点,9号端子为公共点,1号继电器通常用于报警, 2号继电器用于控制外部电磁阀。在仪器断电或报警情况下,5号和6号端子触点断开,6号和7号端子触点接通, 8号和9号端子触点为断开,9号和10号端子触点接通;在仪器接通电源且运行在不报警状态时,5号和6号端子触点接通,6号和7号端子触点断开, 8号和9号端子触点接通,9号和10号端子触点断开。11号和12号端子是为监视油水分离器的运行而设定的,用户必须使用该功能才能符合规范要求。仪器出厂时,11号和12号端子接线端子被短接,请用户将被短接的接线端子断开,然后接一控制油水分离器电机运行的接触器的无源常开触点即可。
4.2 运行
仪器在运行前,必须对仪器进行下列检查:
4.2.1 电气部分:
接地端子是否可靠。
供电电源电压是否与本仪器规定输入电压一致。
4.2.2管路部分:
检查所有管路是否有渗漏现象。
经过上述检查,确认仪器没有问题后,仪器就可进入运行状态。当水样含油浓度等于或大于15PPm,1号报警指示灯在2秒内点亮,同时1号继电器动作。如果水样含油浓度在5秒内还未降到15ppm以下时,2号报警指示灯点亮,同时2号继电器动作。仪器在停止运行前,用清水通入仪器运行2分钟,再将电源开关断开。每次关机后至少停10秒后再开机,以保证仪器正常运行。
4.3 数据打印
打印需要查询的数据时,请输入被查询数据的日期,具体方法如下:
(1)按“1”键,此时面板上显示两位代表年份的数字,且一位数码管不停地闪烁。如果需要修改年份,请直接输入代表当前两位数字的年份,如输入代表当前两位数字的年份“05”,请先按数字键“0”,此时一位数码管停址闪烁,而第二位数码管在不停地闪烁,然后按数字键“5”,则第二位数码管停址闪烁,而一位数码管在不停地闪烁,如果显示的年份正确,请按“确认”键进行确认,此时两位数码管会熄灭一下后继续显示代表年份的两位数字;如果不需要修改年份,也请按“确认”键进行确认,此时两位数码管会熄灭一下后继续显示代表年份的两位数字。
(2)按“2”键,此时面板上显示两位代表月份的数字,且一位数码管不停地闪烁。如果需要修改月份,请直接输入代表当前两位数字的月份,如输入代表当前两位数字的月份“08”,请先按数字键“0”,此时一位数码管停址闪烁,而第二位数码管在不停地闪烁,然后按数字键“8”,则第二位数码管停址闪烁,而一位数码管在不停地闪烁,如果显示的月份正确,请按“确认”键进行确认,此时两位数码管会熄灭一下后继续显示代表月份的两位数字;如果不需要修改月份,也请按“确认”键进行确认,此时两位数码管会熄灭一下后继续显示代表月份的两位数字。
(3)按“3”键,此时面板上显示两位代表日期的数字,且一位数码管不停地闪烁。如果需要修改日期,请直接输入代表当前两位数字的日期,如输入代表当前两位数字的日期“26”,请先按数字键“2”,此时一位数码管停址闪烁,而第二位数码管在不停地闪烁,然后按数字键“6”,则第二位数码管停址闪烁,而一位数码管在不停地闪烁,如果显示的日期正确,请按“确认”键进行确认,此时两位数码管会熄灭一下后继续显示代表日期的两位数字;如果不需要修改日期,也请按“确认”键进行确认,此时两位数码管会熄灭一下后继续显示代表日期的两位数字。
(4)按下“▼”键,再按“打印”键。
打印机就会把某年某月某日的报警数据打印出来。
例:如下打印的数据:
2005-8-26
VAL SEAL SEPA
15:05 10 NORMAL RUN
15:05 16(Alarm) NORMAL RUN
15:10 10 OPEN (Alarm) RUN
15:15 10 OP+CL (Alarm) RUN
15:20 10 CLEAR(Alarm) STOP
15:25 10 NORMAL STOP
当仪器测量的样水浓度大于或等于15ppm、或者用清水清洁仪器,或者仪器箱门打开时,仪器会发出报警并把它记录下来。上述输出的打印格式中,一行的“2005-8-26”代表打印的是报警的日期,一列代表的是记录报警的时间,第二列“VAL”对应的是仪器报警时所对应的浓度,第三列“SEAL”对应的是清洁仪器与箱门的状态,即仪器打开箱门时,对应的状态为“OPEN”,若仪器用清水进行清洁,对应的状态为“CLEAR”,若用清水对仪器进行清洁且箱门打开时,对应的状态为“OP+CL”,若仪器在常态下运行,对应的状态为“NORMAL”;第四列“SEPA”对应的是仪器报警时油水分离器的运行状态,当油水分离器运行时,对应的状态为“RUN”,当油水分离器没有运行时,对应的状态为“STOP”,至于如何监控油水分离器的运行,请参见4.1.4接线一节。如果这一时段仪器没有发生报警,打印机就会打印出“NORMAL”的字样来;如果这一时段仪器没有运行,打印机就会打印出“OFF”的字样