特性
1. 100 mV/g sensitivity
2. 50g range
3. 0.32 to 5,000 Hz frequency range (±5%)
4. 10-foot integral cable
5. 10-32 tapped hole
6. 12 grams
7. Stainless steel
8. Hermetic
9. Case isolated
10. Splash proof boot
11. Moisture resistant
12. IEPE
应用
1. Short-term immersion
2. Structural monitoring
3. Vibration testing in damp environments
参数
PHYSICAL
Weight, Less Cable, Max 0.42 oz 12 grams Supplied Accessories:
Mounting Provision : Tapped Hole 10-32 X .20 Deep 10-32 X .20 Deep
Cable Length 10 FT 25 m
Material : Base, Cap and Connector 300 S.S. 300 S.S.
Sensitivity, ±10% .
Range F.S for ± 5 Volts Output ±50 g ±490 m/s2
Frequency Range ±5% 0.32 to 5000 Hz 0.32 to 5000 Hz
±3 db 0.16 to 10000 Hz 0.16 to 10000 Hz
Resonant Frequency 35 kHz 35 kHz
Equivalent Electrical Noise Floor 0.00001 Grms 0.0001 m/s2 rms
Linearity [3] ± 1% % F.S. ± 1% % F.S.
Maximum Transverse sensitivity 5 % 5 %
Strain Sensitivity, Max 0.001 g/με 0.01 m/s2
Maximum Vibration ±600 G's,peak ±5886 m/s2 peak
Maximum Shock ±3000 G's,peak ±29430 m/s2 peak
Temperature Range -60 to+250 °F -54 to +121 °C
Seal, Accelerometer Hermetic Hermetic
Supply Current Range [4] 2 to 20 mA 2 to 20 mA
Compliance Voltage Range + 18 to +30 Volts + 18 to +30 Volts
Output Impedance,Typ 100 Ω 100 Ω
Bias Voltage +11 to +13 VDC +11 to +13 VDC
Discharge Time C*tant 0.8 to 1.5 Sec 0.8 to 1.5 Sec
Output Signal Polarity for Acceleration Towa* Top Positive Positive
Electrical Isolation, Case Ground to Mounting Surface 10 GΩ,min 10 GΩ,min