General specificati*
Switching function Normally open (NO)
Output type PNP
Rated operating distance 2 mm
Installation flush
Output polarity DC
Assured operating distance 0 ... 1.62 mm
Reduction factor rAl 0.45
Reduction factor rCu 0.35
Reduction factor r304 0.75
Nominal ratings
Operating voltage 10 ... 30 V
Switching frequency 0 ... 1500 Hz
Hysteresis typ. 5%
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Voltage drop ≤ 3 V
Operating current 0 ... 100 mA
Off-state current 0 ... 0.5 mA typ. 0.1 µA
No-load supply current ≤ 15 mA
Switching state indicator Multihole-LED, yellow
Functional safety related parameters
MTTFd 2730 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Approvals and certificates
UL approval cULus Listed, General Pur*e
CSA approval cCSAus Listed, General Pur*e
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditi*
Ambient temperatection type Connector M12 x 1 , 4-pin
Housing material brass, nickel-plated
Sensing face LCP
Housing diameter 8 mm
Degree of protection IP67ure -25 ... 70 °C (-13 ... 158 °F)
Mechanical specificati*
Conn